Skip to main content

Hitachi

Hitachi High-Technologies in Singapore

Liquid Level Transmitter with Remote-sealed Diaphragm EDR-N7FS

We are proud to present the upgrades of the highly-regarded N6 series.

Specifications

Pressure / Differential pressure transmitter Common Specifications
ItemSpecifications
Power supply voltage 11.4~42.0 V DC (16.7~42.0V DC when communication by the communicator)
Output 4~20mA DC
Load resistance 600Ω (at 24V DC power supply voltage)
Ambient temperature limitsWaterproof -20~85°C
Explosion-proof type -20~55°C
Structure Protection code JIS C 0920 IP67
Amplifier case Aluminum alloy
Electrical connection G1/2
Paint color Light gray amplifier case (acid resistant coating)
EDR-N7FS Product Standard Specification (For optional specifications, please refer to the CS sheet)
Item / ModelLiquid level transmitter with remote-sealed diaphragm EDR-N7FS
Range code 8000 40000
Settable range limits -80~80kPa -400~400kPa
Measuring span 2~80kPa 20~400kPa
Accuracy ±0.5% (depending on the measuring span)
Working pressure limits Below the maximum operating pressure of flange
Wetted parts temperature limits -20~180°C
MaterialDiaphragm SUS316L
Other wetted parts SUS316
Process connection JIS 10K 80A flange (100A for flange extension length)
Weight Approx. 10 kg