Skip to main content

Hitachi

Hitachi High-Technologies in Singapore

Absolute Pressure Transmitter with Remote-sealed Diaphragm EDR-N7AS

We are proud to present the upgrades of the highly-regarded N6 series.

Specifications

Pressure / Differential pressure transmitter Common Specifications
ItemSpecifications
Power supply voltage 11.4~42.0 V DC (16.7~42.0V DC when communication by the communicator)
Output 4~20mA DC
Load resistance 600Ω (at 24V DC power supply voltage )
Ambient temperature limitsWaterproof type -20~85°C
Explosion-proof type -20~55°C
Structure Protection code JIS C 0920 IP67
Amplifier case Aluminum alloy
Electrical connection G1/2
Paint color Light gray amplifier case (acid resistant coating)
EDR-N7AS Product Standard Specification (For optional specifications, please refer to the CS sheet)
Item / ModelAbsolute Pressure transmitter with remote-sealed diaphragm EDR-N7AS
Range code 1000 6000
Settable range limits 0~133kPa(abs) 0~798kPa(abs)
Measuring span 13.3~133kPa(abs) 107~798kPa(abs)
Accuracy ±0.5% (depending on the measuring span)
Working pressure limits From 0.133kPa(abs) ~ upper limit of settable range limits
Wetted parts temperature limits -20~180°C
MaterialsDiaphragm SUS316L
Other wetted parts SUS316
Process connection JIS 10K 80A flange (100A for flange extension length)
Weight Approx.9.5 kg