The conventional N6 series has been upgraded.
Items | Specifications | |
---|---|---|
Power supply voltage | DC11.4 - 42.0V DC (16.7 - 42.0 V DC when communication by the communicator) | |
Output | DC4~20mA | |
Load resistance | 600 Ω (at 24V DC power supply voltage) | |
Ambient temperature limits | Waterproof type | -20~85°C |
Explosion-proof | -20~55°C | |
Structure | Protection code JIS C 0920 IP67 | |
Amplifier case | Aluminum alloy | |
Electrical connection | G1/2 | |
Paint color | Light gray amplifier case (acid resistant coating) |
Item / Format | EDR-N7S Differential pressure transmitter with remote-sealed diaphragm | ||
---|---|---|---|
Range code | 8000 | 40000 | |
Settable range limits | 0.8~80kPa | 40~400kPa | |
Measuring span | 2~80kPa | 20~400kPa | |
Accuracy | ±0.2% (depending on the measuring span) | ||
Working pressure limits | Less than the maximum working pressure of flange | ||
Wetted parts temperature limits | -20~180°C | ||
Material | Diaphragm | SUS316L | |
Other wetted parts | SUS316 | ||
Process connection | JIS 10K 80A flange (100A for flange extension length) | ||
Weight | Approx. 10 kg |