The conventional N6 Series has been upgraded.
Items | Specifications | |
---|---|---|
Power supply voltage | 11.4 - 42.0V DC(16.7 - 42.0V DC when communication by the communicator) | |
Output | 4 - 20mA DC | |
Load resistance | 600Ω (at 24V DC power supply voltage) | |
Ambient temperature limits | Waterproof type | -20~85°C |
Explosion-proof type | -20~55°C | |
Structure | Protection code JIS C 0920 IP67 | |
Amplifier case | Aluminum alloy | |
Electrical connection | G1/2 | |
Paint color | Light gray amplifier case(acid resistant coating) |
Item/Model | EDR-N7F Liquid level transmitter | ||
---|---|---|---|
Range code | 8000 | 40000 | |
Settable range limits | -80~80kPa | -400~400kPa | |
Measuring span | 2~80kPa | 20~400kPa | |
Accuracy | ±0.2%(depending on the measuring span) | ||
Working pressure limits | Less than the maximum working pressure of flange | ||
Wetted parts temperature limits | -20 to 180°C(high-pressure side) | ||
Material | Diaphragm | SUS316L | |
Other wetted parts | SUS316 | ||
Process connection | High-pressure side:JIS 10K 80A flange Low-pressure side:Rc 1/4 |
||
Weight | Approx. 10kg |