We are proud to present the upgrades of the highly-regarded N6 series.
Item | Specifications | |
---|---|---|
Power supply voltage | 11.4~42.0 V DC (16.7~42.0V DC when communication by the communicator) | |
Output | 4~20mA DC | |
Load resistance | 600Ω (at 24V DC power supply voltage) | |
Ambient temperature limits | Waterproof type | -20~85°C |
Explosion-proof type |
-20~55°C | |
Structure | Protection code JIS C 0920 IP67 | |
Amplifier case | Aluminum alloy | |
Electrical connection | G1/2 | |
Paint color | Light gray amplifier case (acid resistant coating) |
Item / Model | Sanitary Pressure transmitter EPR-N7SD | |
---|---|---|
Range code | G20 | |
Settable range limits | -98~1MPa | |
Measuring span | 98kPa~1MPa | |
Accuracy | ±0.2% (depending on the measuring span) | |
Working pressure limits | Below 0.98MPa | |
Ambient temperature limits | -10~60°C | |
Wetted parts temperature limits | -20~150°C | |
Material | Diaphragm | SUS316L |
Other wetted parts | SUS316 | |
Process connection | IDF4S clamp connection | |
Capillary tube length | 5m | |
Weight | Approx. 10 kg |