HINL200A Series Computing Unites
The compact plug-in type units receive signals from up to three points, execute a specified operation, and output the appropriate signals. The computing parameters are programmable using the model CMU-1 communicator.
Features
- Removable plug-in structure.
- Does not use an aluminum electrolytic capacitors that has components with limited lifespan.
- Output ZERO / SPAN adjustment section and power lamp is installed on the instrument front, leading to improved maintainability.
Lineup
| Model | Product name | Model | Product name |
|---|---|---|---|
| 210SRA | Square root computing unit | 210WPA | Linearizer |
| 210ADA | Addition and subtraction computing unit | 210FGA | Function generator |
| 210MDA | Multiplication and division computing unit | 210VFA | Voltage / pulse converter |
| 210TPA | Temperature and pressure compensation computing unit | 210FVA | Voltage / pulse converter |
| 210LMA | Limiter | 210AVA | Moving average computing unit |
| 210SLA | Selector | CMU-1 | Communicator |
| 210TLA | Time lag computing unit | CMU-1IF | Communication converter |
Specification
| Model | 210SRA | 210ADA | 210MDA | 210TPA | 210LMA | 210SLA | 210TLA |
|---|---|---|---|---|---|---|---|
| Input signal | 1-5V DC | ||||||
| Output signal | 1-5V DC/4-20mA DC | ||||||
| Allowable load resistance of output signal |
1-5V DC output: above 2kΩ | ||||||
| 4-20mA DC output: below 750Ω | |||||||
| Accuracy | ±0.3% | ±1.0% | ±0.3% | ||||
| Power supply voltage | 85-132V AC 50/60Hz or 24V DC | ||||||
| Power consumption | 100V AC at the time of drive 4.0VA 24V DC at the time of drive 2.4W |
||||||
| Isolation | Input / Output / Between mutual power supply : Yes | ||||||
| Withstand voltage | Between the ground terminal and power supply terminal: 2000V AC, 1 minute Input / Output / Between each mutual power supply: 2000V AC, 1 minute |
||||||
| Insulation resistance | Between each terminal and ground terminal: 100MΩ / 500V DC | ||||||
| Installation method | DIN rail or wall mounting compatible | ||||||
| Weight | Equipment: Approx. 220g Socket: Approx. 80g | ||||||
| Model | 210WPA | 210FGA | 210AVA | 210FVA | 210VFA |
|---|---|---|---|---|---|
| Input signal | 1-5V DC | Pulse signal | DC1-5V | ||
| Output signal | 1-5V DC/4-20mA DC | Open collector | |||
| Allowable load resistance of output signal |
1-5V DC output: above 2kΩ | - | |||
| 4-20mA DC output: below 750Ω | |||||
| Accuracy | ±0.3%FS | ||||
| Power supply voltage | 85-132V AC 50/60Hz or 24V DC | ||||
| Power consumption | 100V AC at the time of drive 4.0VA 24V DC at the time of drive 2.4W |
||||
| Isolation | Input / Output / Between mutual power supply : Yes | ||||
| Withstand voltage | Between the ground terminal and power supply terminal: 2000V AC/ minute Input / Output / Between each mutual power supply: 2000V AC/ minute |
||||
| Insulation resistance | Between each terminal and ground terminal: 100MΩ / 500V DC | ||||
| Installation method | DIN rail or wall mounting compatible | ||||
| Weight | Equipment: Approx. 300g Socket: Approx. 80g | ||||