The EA1200VX High-Sensitivity Element Monitor supports a wide range of applications from RoHS/ELV compliance screening to advanced analysis. Equipped with a unique XRF detector, the Vortex, which features high resolution, sensitivity and count rate, the EA1200VX has remarkably improved overall sensitivity. Using the instrument in combination with the precision control software greatly shortens measurement time.
Measurement times can be greatly shortened, typically to one tenth the time of conventional methods, by combining the high count rate detector and precision control software.
The EA1200VX is equipped with the world's best high count rate detector "Vortex" which samples at a rate of 150,000 cps and does not require LN2, resulting in an unprecedented level of sensitivity and resolution.
Up to five RoHS restricted elements can be measured at one time using a single composite filter, achieving even shorter measuring times from the already rapid measuring time of the EA1200VX.
Measurement of Na to U element is possible by performing measurements in a vacuum condition (with the Light Element Option). This feature also supports highly sensitive analysis of Cl.
With a 1-mmφ x-ray beam, the EA1200VX can perform qualitative and quantitative analyses of micro spots on a printed circuit board.
The optional sample changer enables the continuous measurements of up to 12 samples even under varying measurement conditions. (Optional) Large samples of up to 430 mm × 320 mm in size can also be measured.
Elements | Atomic nos. 11 (Na) to 92 (U) *Atomic nos. when using Vacuum Option |
---|---|
Sample state | Solid / Powder / Liquid |
X-ray source | Small Air-cooled x-ray tube (Rh target) Voltage: 15 kV, 30 kV, 40 kV, 50 kV Current: 1 mA |
X-ray direction | Bottom-up Irradiation |
Detectors | Vortex® (SDD) *No liquid nitrogen required |
Analysis area (beam size) | 1 mm, 8 mm Electric switching |
Sample observation | Color CCD camera |
Chamber | 430(W) × 320(D) × 200(H) mm 239(W) × 280(D) × 66(H) mm (When using vacuum) |
Filter | 5 filters automatic switching |
Controller | Laptop or Desktop |
Qualitative functions | Spectrum measurement, Auto-ID, Comparison display |
Quantitative functions | KLM marker display, Subtraction display, Bulk (FP) CAL, Calibration |
Data Process | Microsoft Excel, Microsoft Word |
Power requirements (Electric box included) | AC 100 V to 120 V, 200 to 240 ±10%, 5 A |
Introducing the example of fluorescent X-ray analysis.
Describing the applications and principles of fluorescent X-ray analysis.
The trademark that represents our strong bond with the customer and shows our pledge to connect science and society to create new value.