Skip to main content

Hitachi High-Tech
  1. Home
  2. Products & Services
  3. Analytical Systems
  4. Atomic Absorption Spectrophotometers (AAS)
  5. Polarized Zeeman Atomic Absorption Spectrophotometer ZA3000 Series

Polarized Zeeman Atomic Absorption Spectrophotometer ZA3000 Series

Polarized Zeeman Atomic Absorption Spectrophotometer ZA3000 Series

Never Ending Evolution of Hitachi Zeeman Atomic Absorption Spectrophotometer !

ZA3000 series developed to meet user’s needs is a new elemental analysis instrument which employs the technology unachievable by other atomic absorption spectrophotometers so as to enhance the functionality and reliability while preserving the basic performance of the polarized Zeeman atomic absorption spectrophotometer, such as high accuracy and high sensitivity.

Features

Enhanced Basic Performance

Graphite furnace analysis gets enhanced accuracy.
By using the specially designed cuvettes, the twin injection function which allows analysis with enhanced accuracy can be utilized.
The power consumption reduction by automatic turning off the hollow cathode lamp during the analysis stand by realizes energy saving.

Introduction of New Functions

The function to automatically detect bumping is introduced for graphite furnace analysis.
Bumping of a sample at the drying stage, which reduces the analysis accuracy, can be automatically detected.
By adding the function to suppress the memory effect and speeding up the dispensing process by the auto sampler, the analysis with better speed and accuracy is also achieved.

Easy Operation and Reliability

The polarized Zeeman correction method by the DC magnetic field, a technology of Hitachi instruments, achieves "Enhanced basic performance" and "Introduction of new functions".
While the background corrections for all elements provide the high reliability, users are strongly supported for their analysis by the software.

Analysis Examples

Flame Analysis of Cd in Brownn RIce

By using the polarized Zeeman correction method which provides a baseline which has high stability, the analysis of Cd in brown rice at a level significantly lower than 0.4 ppm is possible even by flame analysis.

-

Furnace Analysis of Sb in River Water

The twin injection function can measure 0.2 ppb level of Sb without in-furnace concentration.

-

* Pyrotube-D HR is required to use the twin injection function.

Line up

  ZA3000 ZA3300 ZA3700
Flame Analysis  
Graphite Furnace Analysis  

* The polarized Zeeman correction is employed for all the analysis methods.

* Graphite tube C HR(low cost and sensitivity compared with the Graphite tube HR),and conventional Pyro tube HR(7J0-8880)are also available.

Introducing the measurement example using atomic absorption spectrophotometer.

The basics of atomic absorption spectrophotometers, from "Atomic absorption photometer," to "correction method of background (BKG)."

Related Links

Contact Us